1.
Appl Radiat Isot ; 195: 110733, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36841012

RESUMO

The L6 chondritic meteorite, HaH-346, fell in Libya. However, neither the exact date of the fall nor the exact size of the original meteoroid or asteroid is known. A specimen of the meteorite, weighing 488 g, was measured using ultra low-background gamma-ray spectrometry in the 225 m deep underground facility HADES. Activation products 22Na, 26Al, 60Co, 57Co, 54Mn and 44Ti were detected. The detection efficiency was determined by 3D scanning the meteorite and introducing this in the computer model of the detector and sample implemented in the MCNP6.2 Monte Carlo code. The activities of 22Na and 26Al support the hypothesis that the fall took place on 26 August 2018. Furthermore, the 60Co and 26Al activities indicate that the original radius of meteoroid was between 50 and 80 cm, which suggests the mass prior to atmospheric entry was between 2400 and 7300 kg.

2.
Appl Radiat Isot ; 134: 85-88, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29107513

RESUMO

The gamma emitting impurities in 99mTc solution obtained from enriched molybdenum 100Mo metallic target after its irradiation in a cyclotron were measured using a high-purity germanium (HPGe) detector. The radioactivity range of tested samples of 99mTc was rather low, in the range from 0.34 to 2.39 MBq, thus creating a challenge to investigate the standard measurement HPGe system for impurity detection and quantification. In the process of 99mTc separation from irradiated target the AnaLig® Tc-02 resin, Dionex H+ and Alumina A columns were used. Fractions of eluates from various steps of separation process were taken and measured for radionuclidic purity. The overall measurement sensitivity of gamma emitters in terms of minimum detectable activity (MDA) was found at the level of 14-70Bq with emission lines in range of 36 - 1836keV resulting in impurity content range of 6.7 × 10-4 to 3.4 × 10-3 % for 93Tc, 93mTc, 94Tc, 94mTc, 95Tc, 95mTc, 96Tc 96Nb, 97Nb, 99Mo contaminants and 9.4 × 10-3 % for 97mTc. The usefulness of the chosen measurement conditions and the method applied to testing the potential contaminators was proved by reaching satisfactory results of MDAs less than the criteria of impurity concentration of all nuclides specified in the European Pharmacopoeia.

3.
Appl Radiat Isot ; 134: 257-262, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28709738

RESUMO

A comparison of calculations of the activity of a 3H2O liquid scintillation source using the same experimental data set collected at the LNE-LNHB with a triple-to-double coincidence ratio (TDCR) counter was completed. A total of 17 laboratories calculated the activity and standard uncertainty of the LS source using the files with experimental data provided by the LNE-LNHB. The results as well as relevant information on the computation techniques are presented and analysed in this paper. All results are compatible, even if there is a significant dispersion between the reported uncertainties. An output of this comparison is the estimation of the dispersion of TDCR measurement results when measurement conditions are well defined.